Hyperterminal
Hyper Terminal Emulator
HyperTerminal was designed to remotely connect to other computers as well as to provide diagnostic tools to the local computer system. HyperACCESS and HyperTerminal are useful tools for working with networked computers. HyperTerminal is a text-based program, as opposed to a graphical one. Thus, it uses text commands to perform functions. Hyper Terminal Preferences According to the dev team’s goal statement, they started the Hyper project in order to create a, a beautiful and extensible experience for command-line interface users, built on open web standards.
Driver InstallationInsert the iLoad Digital USB Driver CD OR the LoadVUE or LoadVUE Lite CD into your computer's drive. If you have downloaded the driver files from our web site onto a location in your hard disk, substitute that location instead of the CD drive in the instructions below. Drivers for Windows XP and Windows Vista are available here. If you have purchased LoadVUE or LoadVUE Lite software with your iLoad Digital USB load cell, please ensure that you install the drivers as described in this document before you install the LoadVUE software. Also note that the screen shots in this document are for Windows XP, but the process is the same with Windows Vista although the appearance of screens is different. Note: The iLoad series load cells are intended for use with an NRTL approved device such as a computer or regulated power supply. Plug in your iLoad Digital USB load cell into an available USB port on your Windows computer. The New Hardware Wizard window will come up in a few seconds. Select the option for 'No, not this time' and click Next. On the next screen select the option for 'Install the software automatically' option and click Next. Your computer should scan the CD to find appropriate drivers for the load cell. On the next dialog box click Continue Anyway. Windows installs the driver for your iLoad Digital USB load cell. Click Finish. The load cell will appear as a COM port to Windows whenever you plug it in to the same USB port on your computer. If you use a different physical USB port, you may need to go through this procedure again to associate a COM port with that USB port. However, you will usually not have to insert the CD again. To verify the COM port number that has been assigned to the load cell, open the Hardware Device Manager. You can do so by going to the Control Panel in Windows and double-clicking on System. On the System dialog box click on the Hardware tab and select the Device Manager button. When your iLoad Digital USB load cells is connected and correctly installed, you should see a COM port assigned to it as shown highlighted in the following screen shot (next page). If you have more COM ports than you have load cells connected, you can double-click on the entry for a COM port. The ports associated with iLoad Digital USB load cells will indicate that they have a Loadstar Sensors driver as shown below. You are now ready to start using your iLoad Digital USB load cell. Hyperterminal OperationIn Windows XP, launch the Hyperterminal program. Start..All Programs..Accessories..Communications..Hyperterminal Note: Windows Vista does not include a terminal client. However, free terminal client software like Teraterm is available. Set up a new connection to connect to the iLoad Digital USB load cell's COM port. In the 'Connect To' window, select the appropriate COM port. In the 'Port Settings' dialog box, accept the defaults. The baud rate is not applicable to the iLoad USB load cells. Click OK to accept the settings. Then click 'Enter' a few times. You should see the load cell respond with an 'A'. Type 'O0W1' and hit . The load cell will respond with the current load on the load cell in millipounds. In the figure below the load is 2.853 pounds. Type 'CT0' to tare the load cell. This will zero the load (all further readings will subtract the load sensed at this point.) Type 'O0W0' to output the load continuously. Hitting at any time will stop outputting the readings. The iLoad Digital USB load cell can be used through LoadVUE or LoadVUE Lite software from Loadstar Sensors. It can also be used directly as a COM port using any terminal emulation software such as HyperTerminal that is included with Windows XP. To set up Hyperterminal or other terminal emulation program to communicate with the load cell, select the appropriate COM port in the program and connect. Once connected, a few simple commands are all that are needed to operate the load cell:
Since the iLoad Digital USB Load cells present themselves to Windows as COM ports, it is very easy to write your own program to read the load cells loads. Simply open the COM port from your application and send the string O0W1. Divx 10 2 4 – playback divx media. Then read the returned string back in millipounds. We recommend the following steps:
If callbacks (or events) are available, it is preferable to use them instead of polling the load cells in step 7 above. This way Windows will inform the application that there is data to be read. Examples for Labview and Matlab are available on our support pages. | |||||||||||||
If you cannot find what you're looking for or have any other questions please call or This email address is being protected from spambots. You need JavaScript enabled to view it. us and we will be glad to be of further assistance. |
Hyper Terminal 7
HYPERTERMINAL is an IT consult with Head Office in Ibadan, Nigeria. We provide onsite and remote support with computer networking (LAN, WLAN, WAN), and general computer hardware and software solutions, including anti-malware and intrusion prevention. We are adept in website development and general database solutions. Easyping 2 6 1 download free. It can also be used directly as a COM port using any terminal emulation software such as HyperTerminal that is included with Windows XP. To set up Hyperterminal or other terminal emulation program to communicate with the load cell, select the appropriate COM port in the program and connect. Hyperterminal free download - HyperTerminal Private Edition, Windows Me HyperTerminal Buffer Overflow Vulnerability, Windows 2000 HyperTerminal Buffer Overflow Vulnerability Patch, and many more.